Based on the CBCT or CT images taken from the person, design parameters, dimensions and features are determined. The product is completely customised based on the anatomical structure of the person and the data obtained from tomography images. It is not possible to use this designed product in another patient. It is only special for the person for whom it is designed and can only be used in this person.
You can start the order process via our e-mail or telephone number. When our personalised CUSTIMESH™ or CUSTIMPLANT™ products are ready, they are sent by cargo to the address specified by our physicians.
Given that each product is tailored to the needs of a specific patient, Medical CT scans are required for CUSTIMPLANT™ and CBCT scans for CUSTIMESH™. You can send the digital data (DICOM Image) in a single folder via file transfer sites (WeTransfer, Google Drive, etc.). For the design, it is sufficient to send the file containing the DICOM sections.
Subperiosteal implants are a type of titanium implant that is produced individually in accordance with the anatomy of the jawbone of the person in order to restore the lost aesthetics, function and phonation of the person after tooth loss and supports the prosthetic treatment by placing it on the bone. It is especially preferred in extremely atrophic jaws.
In order to achieve osseointegration between CUSTIMPLANT™ and bone, we follow principles such as bone preparation with low rotation speed milling, close contact between the implant and bone and primary stability that allows osseointegration. In addition, RBM is applied only on the surfaces of the implant in contact with the bone, aiming to osseointegrate the bone and the implant as much as possible. The underside of the multiunit attachment points is also polished to a high gloss to prevent bacterial contamination, which is why the CUSTIMPLANT™ surface is classified as a hybrid surface.
Mini screws with a diameter of 1.4-1.5-1.6 mm should be used for Mesh, screws with lengths between 5mm x 2.0 - 12mm x 2.0 for Subperiosteal, and Emergency screws with a diameter of 2.3 mm should be used when necessary.
After the file is sent and payment is made, including the preparation of the design, production processes and shipping, minimum 2 weeks for CUSTIMESH™ and minimum 4 weeks for CUSTIMPLANT™.
Firstly, the patient's CT images (DICOM Image) for CUSTIMPLANT™ and CBCT images (DICOM Image) for CUSTIMESH™ are required. After the relevant physician obtains these images from the patient, the person must send the DICOM files to the e-mail address specified on our website. The images received by e-mail are examined and it is decided whether the image quality is sufficient for the design. If the images are found sufficient for the design, the design phase is started. If necessary, the physician is contacted by telephone or zoom.